EasyManua.ls Logo

Epson AcuLaser C1100 - Page 172

Epson AcuLaser C1100
565 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EPSON AcuLaser C1100 Revision B
TROUBLESHOOTING FIP according to the printer message 172
22
Continuity check of HARNESS ASSY
2BTR SENS
Disconnect P/J620 from HARNESS ASSY
2BTR SENS.
Do all of the wiring below have normal
continuity?
P620-1J111-3
P620-2J111-2
P620-3J111-1
Replace
SENSOR
FUSER IN.
(p.344)
Replace
HARNESS
ASSY 2BTR
SENS.
23
Shape and operation check of CAM ASSY-
2ND
Does CAM ASSY-2ND move smoothly
without any damage, and does it enter the
sensor sensing area?
Go to Step [24]. Replace CAM
ASSY-2ND.
(p.350)
24
Operation check of SENSOR 2BTR
RETRACT
Remove 2ND BTR ASSY. (p.348)
The voltage of P418-6P418-5 on PWBA
MCU is 0 VDC when CAM ASSY-2ND
enters the sensing area of SENSOR 2BTR
RETRACT, and is 5 VDC when it leaves the
sensing area?
Go to Step [27]. Go to Step [25].
25
5 VDC power supply check to SENSOR
2BTR RETRACT
Disconnect P/J418 from PWBA MCU.
The voltage of P418-4P418-5 on PWBA
MCU is 5 VDC?
Go to Step [26]. Go to Step [39].
26
Continuity check of HARNESS ASSY ADC
Disconnect P/J418 from PWBA MCU.
Do all of the wiring below have normal
continuity?
J418-4J112-3
J418-5J112-2
J418-6J112-1
Replace
SENSOR 2BTR
RETRACT.
(p.356)
Replace
HARNESS
ASSY ADC.
Step Check Yes No
27
Continuity check of HARNESS ASSY MAIN
Disconnect the P/J403 from PWBA MCU.
Do all of the wiring below have normal
continuity?
J403-1J600-3
J403-2J600-2
J403-3J600-1
Go to Step [28]. Repair broken
or shorted part.
28
24 VDC power supply check to MOT ASSY
MICRO (2ND BTR Retract Motor)
The voltage of P403-3P403-2 on PWBA
MCU is 24 VDC?
Go to Step [29]. Go to Step [36].
29
Check after replacement of MOT ASSY
MICRO
Replace MOT ASSY MICRO. (p.399)
Does the error recur when a test print is made?
Replace PWBA
MCU. (p.407)
End of
procedure
30
Operation check of EXIT SENSOR in
FUSER ASSY
The voltage of P417-8P417-7 on PWBA
MCU is 0 VDC when ACTUATOR enters the
sensing area of EXIT SENSOR, and is
5 VDC when it leaves the sensing area?
Go to Step [33]. Go to Step [31].
31
5 VDC power supply check to EXIT
SENSOR in FUSER ASSY
Allow FUSER ASSY to cool down
before performing work.
Remove FUSER ASSY. (p.388)
The voltage of connector J614A-7 J614A-6
that connects FUSER ASSY on the printer is 5
VDC?
Go to Step [32]. Go to Step [38].
Step Check Yes No
W A R N I N G

Table of Contents

Other manuals for Epson AcuLaser C1100

Related product manuals