AcuLaser M2000D/M2000DN/M2010D/M2010DN Revision B
OPERATING PRINCIPLES      Electrical parts layout 18
Confidential
OTHER ELECTRICAL COMPONENTS
Figure 2-3.  Other electrical components
1. Main motor 
Drives the paper feed/conveying section and fuser unit.
2. Polygon motor 
Drives the polygon mirror.
3. Right cooling fan motor 
Cools the interior of machine.
4. Left cooling fan motor 
Cools the interior of machine.
5. Registration clutch 
Controls the secondary paper feed.
6. Paper feed clutch 
Controls the paper cassette paper feed.
7. Developing clutch 
Controls the toner feed.
8. Duplex solenoid 
Controls the paper conveying at the duplex conveying section.
9. MP paper feed solenoid 
Controls the MPF bottom plate of the MP tray.
10. Fuser heater lamp 
Heats the heat roller.
1
2
3
4
10
5
9
7
6
8
Machine inside
Machine left