EPSON AcuLaser M2000D/M2000DN/M2010D/M2010DN Revision B
TROUBLESHOOTING Symptoms 36
Confidential
3.3.3 Electrical Problems
3.3.4 Mechanical Problems
Toner smudges
Toner smudges appear on the top edge or non-
printed side of the page.
Page 60
Wavy image
The printed image on the upper right side
(scanning start position) of the page is wavy.
Page 60
Symptom Reference
ABC
123
Symptom Reference
The machine does not operate when the power switch is turned on.
Page 61
Right cooling fan motor does not operate.
Left cooling fan motor does not operate.
Power supply fan motor does not operate.
Registration clutch does not operate.
Paper feed clutch does not operate.
Developing clutch does not operate.
MP paper feed solenoid does not operate.
Duplex solenoid does not operate.
Eraser lamp does not turn on.
The machine does not detect paper loaded in the cassette.
A paper jam in the paper feed/conveying section or fuser section is indicated
when the power switch is turned on.
The machine does not detect that the top cover is closed.
Symptom Reference
No primary paper feed.
Page 63
No secondary paper feed.
Skewed paper feed.
Multiple sheets of paper are fed at one time.
Paper jams.
Toner drops on the paper conveying path.
Abnormal noise is heard.
Paper becomes wrinkled, creased, or curled.