A Menu Structure FLUXUS G60x
UMFLUXUS_G6V4-2EN, 2011-03-29 187
Install Medium
selection of the displays for the input of media
Install Medium with Special Funct.\SYSTEM settings\
Libraries\Extended Library = off
selection whether a user defined medium is to
be edited or deleted
selection of a user defined medium
input of a designation for the selected medium
input of the min. sound speed of the medium
range: 800...3500 m/s
input of the max. sound speed of the medium
input of the kinematic viscosity of the medium
range: 0.01...30 000.00 mm
2
/s
input of the operating density of the medium
Install Medium with Special Funct.\SYSTEM settings\
Libraries\Extended Library = on
selection of the function for the temperature and
pressure dependency of the medium properties
cold start
resistant
Special Funct.
Install Medium
Install Medium
>EDIT< delete
USER Medium
#01:--not used--
EDIT TEXT
(
↑↓← 
USER MEDIUM 1
c-Medium MIN
1400.0 m/s
c-Medium MAX
1550.0 m/s
Kinem.Viscosity
1.01 mm2/s
Density
60.00 kg/m3
Edit Medium
Basics:Y=m*X +n