Chapter 11 System Management
11.2 Functions in the Action Area for System
ETERNUS Web GUI User’s Guide
551
Copyright 2011 FUJITSU LIMITED P2X0-1090-02ENZ0
Setting based on Severity
Select whether to notify of an event by levels. Checkboxes are displayed for selectable
notification methods.
All Error Events
Select whether to notify when an error level event occurs. When notifying, select the
notification method.
All Warning Events
Select whether to notify when a warning level event occurs. When notifying, select the
notification method.
All Informational Events
Select whether to notify when a informational level event occurs. When notifying, select
the notification method.
Individual Settings within Severity Level
"Yes" is displayed when the target notification method ("Host Sense Key Code
Qualifier", "SNMP Trap", "E-Mail", "syslog" or "REMCS") is specified for any event in
"Error Severity Level", "Warning Level", or "Informational Level", if not, "No" is
displayed.
Error Severity Level
Select whether to notify of the error event for each event type.
Parts Error
Select whether to notify when a failure occurs in a component other than the drive.
When notifying, select the notification method.
Disk Error
Select whether to notify when a drive failure occurs for each condition shown below.
When notifying, select the notification method.
- Any Time
Notifies always when a drive failure occurs.
- when HS<0
Notifies only when a drive failure occurs while available hot spare disk is "Less than
0" (*1).
*1: When rebuilding cannot be performed because there are no hot spares that can be
used as a substitute for the failed drive.
Temperature Error
Select whether to notify when a temperature error status is detected by the sensor.
When notifying, select the notification method.
End of battery life
Select whether to notify when a battery expires. When notifying, select the notification
method.
"Time limit of the buttery cuts" notification is available only for ETERNUS DX410 S2/
DX440 S2.