Chapter 11 System Management
11.2 Functions in the Action Area for System
ETERNUS Web GUI User’s Guide
552
Copyright 2011 FUJITSU LIMITED P2X0-1090-02ENZ0
• Rebuild/Copyback w/ redundant
Select whether to notify when rebuilding or copy backing (with redundancy) (*1) is per-
formed. When notifying, select the notification method.
*1: "Rebuilding to hot spare disk is complete", "Copyback starts" and "Copyback complete"
are equivalent to "Redundancy".
• Rebuild/Copyback w/o redundant
Select whether to notify when rebuilding or copy backing (without redundancy) (*1)
occurs for each condition shown below. When notifying, select the notification method.
- Any Time
Notifies always when rebuilding or copy backing (without redundancy) occurs.
- when HS<0
Notifies only when rebuilding or copy backing (without redundancy) occurs while
available hot spare disk is "Less than 0".
*1: "Rebuild to hot spare disk is started", "Rebuild to hot spare disk failed" and "Copyback
failed" are equivalent to "Without redundancy".
• Complete rebuild
Select whether to notify when a bad sector (*1) is detected in the hot spare where
rebuilding is completed. When notifying, select the notification method.
*1: A bad sector is the location information (address and length) where an error such as data
reading error occurs during rebuild, copyback, or redundant copy.
• Bad data
Select whether to notify when a bad sector is detected in the drive. When notifying,
select the notification method.
• Pinned data
Select whether to notify when the pinned data (*1) is detected. When notifying, select
the notification method.
*1: "Pinned data" is the data left in the cache due to unsuccessful write-back to the drive from
the cache area.
• Not ready
Select whether to notify when the ETERNUS DX Disk storage system is in "Not ready"
status (*1). When notifying, select the notification method.
*1: "Not ready" is the status in which the ETERNUS DX Disk storage system cannot operate
properly due to a cause such as failures in multiple components.
• Remote Path Error
Select whether to notify when an REC path error occurs. When notifying, select the
notification method.
• REC Buffer Halt (Path Error)
Select whether to notify when an REC buffer halt caused by REC path error occurs.
When notifying, select the notification method.
• REC Buffer Halt (Overload)
Select whether to notify when an REC buffer halt caused by overload occurs. When
notifying, select the notification method.
• REC Buffer Halt (Other Error)
Select whether to notify when an REC buffer halt caused by an error occurs. When
notifying, select the notification method.