EasyManuals Logo

Fujitsu SPARC Enterprise M5000 User Manual

Fujitsu SPARC Enterprise M5000
310 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #210 background imageLoading...
Page #210 background image
12-14 SPARC Enterprise M4000/M5000 Servers Service Manual December 2010
3. Confirm that the installed CPU module is recognized by the server and that the
error indicator asterisk (*) is not displayed.
4. Confirm that no error has occurred.
5. Change the key position on the operator panel from Service to Locked.
6. Set the following for the CPU module:
Set up XSB.
Set up the LSB.
Add the XSB to the domain.
Set up the CPU operational mode on the domain.
Refer to Chapter 2, “Setting Up XSCF,” in the SPARC Enterprise
M3000/M4000/M5000/M8000/M9000 Servers XSCF Users Guide for information
about these settings.
7. Power on all the domains.
8. Confirm that all the domains have been correctly started.
9. Confirm that no error has occurred.
XSCF> showhardconf -M
XSCF> showlogs error -v
XSCF> showstatus
XSCF> poweron -a
XSCF> showlogs power
XSCF> showlogs error -v
XSCF> showstatus

Table of Contents

Other manuals for Fujitsu SPARC Enterprise M5000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu SPARC Enterprise M5000 and is the answer not in the manual?

Fujitsu SPARC Enterprise M5000 Specifications

General IconGeneral
BrandFujitsu
ModelSPARC Enterprise M5000
CategoryServer
LanguageEnglish

Related product manuals