12-14 SPARC Enterprise M4000/M5000 Servers Service Manual December 2010
3. Confirm that the installed CPU module is recognized by the server and that the
error indicator asterisk (*) is not displayed.
4. Confirm that no error has occurred.
5. Change the key position on the operator panel from Service to Locked.
6. Set the following for the CPU module:
Set up XSB.
Set up the LSB.
Add the XSB to the domain.
Set up the CPU operational mode on the domain.
Refer to Chapter 2, “Setting Up XSCF,” in the SPARC Enterprise
M3000/M4000/M5000/M8000/M9000 Servers XSCF Users Guide for information
about these settings.
7. Power on all the domains.
8. Confirm that all the domains have been correctly started.
9. Confirm that no error has occurred.
XSCF> showhardconf -M
XSCF> showlogs error -v
XSCF> showstatus
XSCF> poweron -a
XSCF> showlogs power
XSCF> showlogs error -v
XSCF> showstatus