5.4.2 TeamCOMBO Board Settings
Switch Definition Settings (Default in Bold)
Port 1/2 DC Powered or Standard COM-I/F for
Port 1/2
PORT 1 STD COM DC Powered
PORT 2 STD COM DC Powered
* Two jumpers requird for each setting.
SW3
1
UART Base Address in MCP Mode
ON 0230H OFF 0100H
2 Parallel Port Address
ON 0278H OFF 0378H
3 Mode (Must be set to off)
ON N/A OFF MCP
4 COM COM Port Mode
ON COM 3/4 OFF Multi-Com
5 BATL Detect Lead Acid Battery Alarm
ON Enable OFF Disable
6 FAN1 Detect CPU Fan Alarm
ON Enable OFF Disable
7 FAN 2 Detect PSU FAN Alarm
ON Enable OFF Disalbe
8 FAN3 Detect Chassis FAN Alarm
ON Enable OFF Disable
ISA/IRQ IRQ12 S
ON Enable OFF Disable
IRQ11 E O O
ON Enable OFF Disable
IRQ10 L N N ON Enable OFF Disable
IRQ9 E L E
ON Enable OFF Disable
IRQ7 C Y
ON Enable OFF Disable
IRQ5 T
ON Enable OFF Disable
SW1
COM3 IRQ
Only one IRQ switch can be ON
Note: Only applies when SW3
position 4 is set for COM 3/4
IRQ3 OFF IRQ10 OFF
IRQ4 ON IRQ11 OFF
IRQ9 OFF IRQ12 OFF
SW2
COM4 IRQ
Only one IRQ switch can be ON
Note: Only applies when SW3,
position 4 is set for COM 3/4
IRQ3 ON IRQ10 OFF
IRQ4 OFF IRQ11 OFF
IRQ9 OFF IRQ12 OFF
90000291 Rev 3.0 5-19