CABLE LIST
HAAS AUTOMATION, INC.
SERVICE
MANUAL
VF-SERIES
CABLE LIST
The following is a summary of the cables used in the wiring of this control:
WIRE/
TERMINAL FUNCTION NAME:
NUMBER
GND INCOMING EARTH GROUND #8
-FROM INCOMING POWER GROUND
-TO CHASSIS GROUND
-TO 160 VDC RETURN
-TO SHIELD OF ALL BULK CABLES
-TO LOGIC RETURN (D GROUND 65)
L1 INCOMING 230VAC, PHASE 1, TO CB1-1 #10
L2 INCOMING 230VAC, PHASE 2, TO CB1-2 #10
L3 INCOMING 230VAC, PHASE 3, TO CB1-3 #10
L4 230VAC, PHASE 1, CB1 TO K1-1 #10
L5 230VAC, PHASE 2, CB1 TO K1-2 #10
L6 230VAC, PHASE 3, CB1 TO K1-3 #10
R/L7 230VAC FROM K1 TO SPINDLE DRIVE, PHASE 1 #10
S/L8 230VAC FROM K1 TO SPINDLE DRIVE, PHASE 2 #10
T/L9 230VAC FROM K1 TO SPINDLE DRIVE, PHASE 3 #10
71/L4 FUSED 230 VAC (FROM MAIN CB1-4 TO K1-1) #10
72/L5 FUSED 230 VAC (FROM MAIN CB1-5 TO K1-2) #10
73/L6 FUSED 230 VAC (FROM MAIN CB1-6 TO K1-3) #10
74/R 230 VAC (FROM MAIN CONTACTOR K1-4) #12
75/S 230 VAC (FROM MAIN CONTACTOR K1-5) #12
76/T 230 VAC (FROM MAIN CONTACTOR K1-6) #12
77 230VAC FUSED 12A TO 3 PH XFORMER T1 #12
78 230VAC FUSED 12A TO 3 PH XFORMER T1 #12
79 230VAC FUSED 12A TO 3 PH XFORMER T1 #12
80 DISTRIBUTED 160 VDC - SHIELD +2
81 +160 VDC HIGH VOLTAGE SUPPLY #16
82 160 VDC RETURN #16
90 115 VAC FROM TRANSFORMER T1
91/U STEPPED-DOWN 115 VAC (FROM XFRMER T1) #12
92/V STEPPED-DOWN 115 VAC (FROM XFRMER T1) #12
93/W STEPPED-DOWN 115 VAC (FROM XFRMER T1) #12
90A 115 VAC TO CRT - SHIELD +2
92 LEG 1 #16