WE2107 - Communication commands
80
I1820-1.3 enHBM
Error bits 30 Error parameter (Bit 5 = 1)
0 ‐ ( no or several errors)
1 Factory characteristic to sensitive
( SFA – SZA < 2000)
2 Scale characteristic to sensitive
( LWT – LDW < 2000)
3 Linearization parameter
LIN1> LIN2 or LIM1> LIM2
4 Gross value overflow
1)
5 Linearization curve, no solution
6 Gross value underflow 1)
7 Initial zero setting value out of range (ZSE)
8 zeroing failed
9 tare failed
10 dosing time overflow
11 weight in the bin/tank is larger than the start limit
12 weight in the tank is too small to dosing
13 dosing: sum is out of range
14 Printing: not standstill over 5 sec. When LFT>0
1)
out of display range
Error bits 30 Error communication (Bit 4 = 1)
0 ‐ ( no or several errors)
1 Parameter input out of range
2 Unknown command
3 Password (DPW) failed
4 Parameter write protected (LFT>0, or/and password)
5 Printing time out
6 Calibration counter overflow (TCR>65535)
7 COM1 : framing, parity, break
8 Total weight (sum) overflow

Table of Contents