l Take measures to protect the power system from the interference of the power grid.
l Separate the protection ground of the device from the grounding device or lighting protection
grounding device of the power supply equipment as far as possible.
l Keep the device away from radio stations, radar, and other high-frequency and high-current
devices.
l Use electromagnetic shielding when necessary.
Grounding Requirements
To use the device more safely:
l Ensure that the grounding screw of the chassis is well grounded via the grounding cable.
l Ensure that the grounding pin of the power plug is well grounded.
Cabinet Requirements
The SG-6000X-Series device (except desktop models) is designed to fit in a standard 19-inch cab-
inet. They can be installed in a 19-inch (or larger) cabinet.
Cabinet Size and Clearance Requirements
The minimum size that can accommodate the device is a 19-inch standard cabinet. A larger cab-
inet can provide better air flow and reduce the chance of overheating.
To prevent overheating, the cabinet that accommodates the device should have certain clearance
around the device.
Cabinet Airflow Requirements
When a device is mounted in a cabinet, you must ensure that the ventilation through the cabinet
conforms to the following requirements:
Chapter 2 Installation Preparations 120