Assembly and Commissioning Instructions Servo amplifier D1-N 15.10.2015
In the following step the motor is energised with a frequency of around 25 Hz
and starts to oscillate this way and that. If necessary, you can abort the pro-
cess at any time by deactivating the “HW enable” or pressing the “F12” but-
ton.
Tick
and click on the
button. Please ensure
that the motor has enough space to move a little in both directions and that the
mechanical brake is open (if fitted). Start the process by clicking on the
but-
ton.
Figure 9.14: Frequency analyser in “Simple Mode”
Select the
tab to determine general control parameters. Please
ensure that the motor has enough space to move a little in both directions and that
the mechanical brake is open (if fitted). Start the process with the
button.
The “hardware enable” and “SM enable” must be active for the measurement.