Assembly and Commissioning Instructions Servo amplifier D1-N 15.10.2015
129 / 183
Simple Version
CAUTION!
In the following step the motor is energised with a frequency of around 25 Hz
and starts to oscillate this way and that. If necessary, you can abort the pro-
cess at any time by deactivating the HW enable or pressing the “F12but-
ton.
Tick
Use simple version
and click on the
Freq analyzer
button. Please ensure
that the motor has enough space to move a little in both directions and that the
mechanical brake is open (if fitted). Start the process by clicking on the
Run
but-
ton.
Figure 9.14: Frequency analyser in “Simple Mode
Thorough “Freq analyzer
Select the
Step./dcbl plant
tab to determine general control parameters. Please
ensure that the motor has enough space to move a little in both directions and that
the mechanical brake is open (if fitted). Start the process with the
Run
button.
The hardware enableand SM enablemust be active for the measurement.