6 - 3
Passwords
A password must be configured. If the password is not configured, a new device switches into Administration mode without
prompting for a password. In addition to the Administrator hotkey press, a mode switch occurs if inaccurate information has
been configured or if mandatory information is missing in the configuration.
There are several situations that display a password prompt after a password has been configured.
If the configured hotkey is pressed, the password prompt is displayed. In this case the user has 30 seconds (and within three
attempts) to enter a password. If a valid password is not entered within 30 seconds, the password prompt is dismissed and the
device returns to end user mode.
All other situations that present the password prompt do not dismiss the prompt -- this is because the other situations result in
invalid end user operation.
These conditions include:
If inaccurate configuration information is entered by the administrator, i.e., an application is specified that does not exist.
If the application name, which is mandatory for end user mode, is missing in the configuration.
Invalid installation of AppLock (e.g., missing DLLs).
Corrupted registry settings.
To summarize, if an error occurs that prevents AppLock from switching to end user mode, the password will not timeout and
AppLock will wait until the correct password is entered.
AppLock Password Help
Contact Technical Assistance (page 16-1) when troubleshooting passwords.
End-User Switching Technique
The default end user Hotkey Activation key is Ctrl+Spc..
Switchpad Menu
A check mark indicates applications currently active or available for Launching by the user. When Keyboard is selected, the MX7
Tecton default input method (Input Panel, Transcriber, or custom input method) is activated.
The check mark to the left of the application name indicates that the application is active.
If the application is listed but does not have a check mark to the left of the application name, this means the application is con-
figured in AppLock and can be manually launched by tapping on the application name in the list.
Using a Stylus Tap
When the mobile device enters end user mode, a Switchpad icon (it looks like three tiny windows one above the other) is
displayed in the lower right corner of the display. The Switchpad is always visible on top of the application in focus. How-
ever, if only one application is configured in AppLock and the Input Panel is disabled the Switchpad is not visible.
When the user taps the Switchpad icon, a menu is displayed showing the applications available to the user. The user can
tap an application name in the popup menu and the selected application is brought to the foreground. The previous applica-
tion continues to run in the background. Stylus taps affect the application in focus only. When the user needs to use the
Input Panel, they tap the Keyboard option. Input Panel taps affect the application in focus only.
Using the Switch Key Sequence
One switch key sequence (or hotkey) is defined by the administrator for the end user to use when switching between locked
applications. This is known as the Activation key. The Activation key is assigned by the Administrator using the Global Key
setting in the Application panel.

Table of Contents

Other manuals for Honeywell MX7 Tecton

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell MX7 Tecton and is the answer not in the manual?

Honeywell MX7 Tecton Specifications

General IconGeneral
Display diagonal3.5 \
Display resolution240 x 320 pixels
Display number of colors-
Internal memory0.256 GB
Internal memory typeRAM
Compatible memory cardsSD
Maximum memory card size4 GB
Processor familyPXA 320
Processor frequency0.806 GHz
GPS (satellite)No
Operating system installed Windows CE 6.0
Wi-Fi standards802.11a, 802.11b, 802.11g
Bluetooth version2.0+EDR
Headphone outputs1
USB 2.0 ports quantityUSB 2.0 ports have a data transmission speed of 480 Mbps, and are backwards compatible with USB 1.1 ports. You can connect all kinds of peripheral devices to them.
Storage temperature (T-T)-20 - 70 °C
Operating temperature (T-T)-30 - 50 °C
Operating relative humidity (H-H)5 - 100 %
Battery capacity2200 mAh
AC adapter output current7.4 A
Product colorBlack, Blue
Keyboard layoutAlphanumeric
Linear (1D) barcodes supportedCodabar, Code 128, Code 39, Code 93, EAN-13, GS1-128 (UCC/EAN-128), PLANET, Plessey, Telepen, Trioptic, U.P.C.
2D (matrix & stacked) barcodes supportedAztec Code, Code 49, Data Matrix, MaxiCode, MicroPDF417, PDF417, QR Code
Weight and Dimensions IconWeight and Dimensions
Depth50 mm
Width86 mm
Height223 mm
Weight595 g