EasyManuals Logo

Honeywell MX7 Tecton User Manual

Honeywell MX7 Tecton
354 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #138 background imageLoading...
Page #138 background image
6 - 12
Log
Note: If a level higher than Error is selected, the status should be cleared frequently by the administrator.
In addition to the three view levels the administrator can select that all status information be logged or turn off all status
information logging completely. The system default is ‘None’; however to reduce registry use, the administrator may
want to select ‘None’ after verifying the configuration. Tap the Clear button to clear the status information from the reg-
istry.
•None
Error
Processing
Extended
•All
Save As
When the 'Save As'… button is selected, a standard 'Save As' dialog screen is displayed. Specify the path and file-
name. If the filename exists, the user is prompted whether the file should be overwritten. If the file does not exist, it is
created.
AppLock Help
Issue:
The MX7 Tecton won’t switch from Administration mode to end user mode.
Solution:
If the configuration is valid for one application but not the other, the switch to end user mode fails. AppLock stays in
Administration mode and is paused until the Administrator password is entered.
If two copies of the same application are configured, but the application only allows one copy to run at a time, for example
Microsoft Pocket Word and RFTerm, the switch to end user fails. AppLock stays in Administration mode and is paused
until the Administrator password is entered.
Issue:
The hotkey sequence needed is not allowed. What does this mean?
Solution:
When the Administrator is selecting a hotkey sequence to use when switching user modes, they are not allowed to enter
key combinations that are reserved by installed software applications. Honeywell has validated RFTerm key combinations
ONLY.
When RFTerm is installed on the mobile device and an RFTerm restricted key sequence is specified as a hotkey sequence
by the Administrator, the following error message is displayed in a message box:
Selected hotkey is not allowed. Please reenter.
When RFTerm is not installed on the mobile device, the RFTerm keys are not restricted from use.
Issue:
Can’t locate the password that has been set by the administrator?
Solution:
Contact Technical Assistance (page 16-1) for administrator password help.

Table of Contents

Other manuals for Honeywell MX7 Tecton

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell MX7 Tecton and is the answer not in the manual?

Honeywell MX7 Tecton Specifications

General IconGeneral
Display diagonal3.5 \
Display resolution240 x 320 pixels
Display number of colors-
Internal memory0.256 GB
Internal memory typeRAM
Compatible memory cardsSD
Maximum memory card size4 GB
Processor familyPXA 320
Processor frequency0.806 GHz
GPS (satellite)No
Operating system installed Windows CE 6.0
Wi-Fi standards802.11a, 802.11b, 802.11g
Bluetooth version2.0+EDR
Headphone outputs1
USB 2.0 ports quantityUSB 2.0 ports have a data transmission speed of 480 Mbps, and are backwards compatible with USB 1.1 ports. You can connect all kinds of peripheral devices to them.
Storage temperature (T-T)-20 - 70 °C
Operating temperature (T-T)-30 - 50 °C
Operating relative humidity (H-H)5 - 100 %
Battery capacity2200 mAh
AC adapter output current7.4 A
Product colorBlack, Blue
Keyboard layoutAlphanumeric
Linear (1D) barcodes supportedCodabar, Code 128, Code 39, Code 93, EAN-13, GS1-128 (UCC/EAN-128), PLANET, Plessey, Telepen, Trioptic, U.P.C.
2D (matrix & stacked) barcodes supportedAztec Code, Code 49, Data Matrix, MaxiCode, MicroPDF417, PDF417, QR Code
Weight and Dimensions IconWeight and Dimensions
Depth50 mm
Width86 mm
Height223 mm
Weight595 g

Related product manuals