EasyManua.ls Logo

Honeywell MX7 Tecton - Page 179

Honeywell MX7 Tecton
354 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8 - 23
OCR Properties - Advanced
Font – Font selection. Default is disabled.
•A = OCR A
•B = OCR B
Money = OCR Money
MICR = Magnetic Ink Character Recognition
Direction – Decoder reads OCR fonts in any direction, but setting direction parameter correctly can increase
decoding speed. Default is Left to Right.
Template – Template length must match the length of OCR string to be read. Default is dddddddd. Valid template
selections are:
a - alphanumeric character (digit or letter)
c - check character
d - digits from 0 to 9
e - any character
g - any character specified in group G
h - any character specified in group H
l - alphabetic letter
r - delimits a row
t - delimits multiple templates
All characters are transmitted as is except for the selected template.
Group G – Null terminated string defines the set of characters in group G. The default is null.
Group H – Null terminated string defines the set of characters in group H. The default is null.
Check – Enter the string constant 0123456789 for modulo10 checksums and the string constant 0123456789AB-
CDEFGHIJKLMNOPQRSTUVWXYZ for modulo36 checksums.
The default is null.
OCR Template Examples
1. To read a combination of 6 alpha and numeric characters use the following template:
aaaaaa

Table of Contents

Other manuals for Honeywell MX7 Tecton

Related product manuals