EasyManua.ls Logo

Honeywell UMC800 - SUB Function Block; Table 5-82 SUB Dynamic Parameters

Honeywell UMC800
152 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Function Parameter Index Reference
8/99 RS232 Communications Reference Manual 115
5.62 SUB Function Block
Description
The SUB label stands for the Subtraction mathematical operation (2 Inputs). This block is part of the
Math category. It looks like this graphically on the Control Builder.
Dynamic Parameters:
Table 5-82 SUB Dynamic Parameters
Parameter Index Type Use R/W Description
status 0 REAL C R block status (see section 5.2 for code list)
OUT 1 REAL O R output
X 2 REAL I R input 1
Y 3 REAL I R input 2
Static Configuration Parameters:
None