EasyManuals Logo

IAI SEL User Manual

Default Icon
324 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #237 background imageLoading...
Page #237 background image
16. Controller
219
202
18.3. Software Reset
Executes software reset of the controller. The data which is not written to Flash ROM will be
cleared.
Select the F2 (SRst) key on the controller item screen.
Mode Transition:
To execute a software reset, press the F1 (Yes) key.
If not, press the F2 (No) key. The screen returns to
the mode selection screen.
18.4. Error Reset
Executes error reset of the controller. Reset the message-level and action-release-level errors. If
the cause of the error is not solved, the error will reoccur again.
Select the F3 (ERst) key on the controller item screen.
Mode Transition:
To execute an error reset, press the F1 (Yes) key.
If not, press the F2 (No) key.
The screen returns to the controller item screen.
16.3.
16.4.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IAI SEL and is the answer not in the manual?

IAI SEL Specifications

General IconGeneral
Protection ClassIP20
CommunicationRS-232C
Control MethodPTP
Number of AxesUp to 4 axes
Vibration Resistance4.9 m/s² (0.5 G)
Humidity20 to 85% RH (non-condensing)