Parameter Description
file The file path and the file name to which you want to
save the performance statistics. Enclose the file name in
double quotation marks (" "). For example:
file="C:\Program Files\CLI\sup\ibstat.txt"
This command does not automatically append a file
extension to the saved file. You must specify a file
extension when entering the file name.
Notes
If you have not reset the InfiniBand baseline statistics since the controller start-of-day, the time at the
start-of-day is the default baseline time.
Minimum Firmware Level
7.32
Save Storage Subsystem iSCSI Statistics
This command saves the iSCSI performance statistics of the storage subsystem to a file.
Syntax
save storageSubsystem iscsiStatistics [raw | baseline]
file=“filename”
Parameters
Parameter Description
raw The statistics collected are all statistics from the controller
start-of-day. Enclose the parameter in square brackets ([ ]).
baseline The statistics that are collected are all statistics from the time the
controllers were reset to zero using the reset storageSubsystem
iscsiStatsBaseline command. Enclose the parameter in square
brackets ([ ]).
file The name of the file to which you want to save the performance
statistics. Enclose the file name in double quotation marks (“ ”).
Notes
If you have not reset the iSCSI baseline statistics since the controller start–of–day, the time at the
start–of–day is the default baseline time.
Save Storage Subsystem Performance Statistics
This command saves the performance statistics to a file. Before you use this command, run the set
session performanceMonitorInterval command and the set session performanceMonitorIterations
command to specify how often statistics are collected.
Chapter 3. Script Commands 3-179