The set storageSubsystem isnsServerRefresh command returns an error if you did not set the
configuration method to DHCP. To set the configuration method to DHCP, use the set storageSubsystem
isnsIPV4ConfigurationMethod command.
Set Storage Subsystem Learn Cycle
This command sets the learn cycle for the battery backup unit, which enables the storage management
software to predict the remaining battery life. Learn cycles run at set intervals, and they store the results
for software analysis.
Syntax
set storageSubsystem learnCycleDate
(daysToNextLearnCycle=numberOfDays |
day=dayOfTheWeek) time=HH:MM
Parameters
Parameter Description
daysToNextLearnCycle Valid values are 0 through 7, where 0 is immediately and 7 is in seven days.
The daysToNextLearnCycle parameter takes place up to seven days after the
next scheduled learn cycle.
day Valid values for the day parameter include the days of the week (Sunday,
Monday, Tuesday, Wednesday, Thursday, Friday, and Saturday). Setting the day
causes the next learn cycle to be scheduled on the specified day, after the
currently scheduled learn cycle.
time The time in 24-hour format; for example 8:00 a.m. is entered as 08:00. Nine
o’clock p.m. is entered as 21:00, and 9:30 p.m. is entered as 21:30.
Notes
You can set the learn cycle to occur only once during a seven-day period.
The time parameter selects a specific time that you want to run the learn cycle. If a value is not entered,
the command uses a default value of 00:00 (midnight).
If the day and time specified are in the past, the next learn cycle takes place on the next possible day
specified.
Set Storage Subsystem Redundancy Mode
This command sets the redundancy mode of the storage subsystem to either simplex or duplex.
Syntax
set storageSubsystem redundancyMode=(simplex | duplex)
Parameter
Parameter Description
redundancyMode Use simplex mode when you have a single controller. Use
duplex mode when you have two controllers.
3-242 IBM System Storage DS3000, DS4000, and DS5000: Command Line Interface and Script Commands Programming Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System Storage DS3000 and is the answer not in the manual?

IBM System Storage DS3000 Specifications

General IconGeneral
BrandIBM
ModelSystem Storage DS3000
CategoryStorage
LanguageEnglish

Related product manuals