Crane Fault Codes 148 Section - 21
Operator’s - Manual # 99906363
Crane—Fault Table
HELP
MESSAGE DTC
STOP
ICON
WARN
ICON ACTION TRIGGER LATCH
Power Cycle 0 OFF OFF · No restrictions This Help Message is issued
at each power-up. This
serves to indicate which mes-
sages have been recorded in
the failure log since the last
power-up event.
Unlatched
Everything
Ok
1 OFF OFF · No restrictions No Faults are active. Unlatched
Crane Bat-
tery Voltage
Too Low
212 ON ON • Crane Functions =
PREVENTED
System voltage is < 9.0 volts
for 5000 mS.
Unlatched
• Horn = PREVENT-
ED
• Boom Tip Lights =
PREVENTED
Crane Bat-
tery Voltage
Too High
213 ON ON
with
Pop
UP
• Crane Functions =
PREVENTED
System voltage > 18 volts for
5000 mS.
Unlatched
• Horn = PREVENT-
ED
• Boom Tip Lights =
PREVENTED
Load Pres-
sure Sensor
Piston Out of
Range High
220 OFF ON • Boom Lift Down =
PREVENTED
Sensor Current > 22.0mA for
500mS
latched
• Boom Telescope
Out = PREVENTED
• Winch Up = PRE-
VENTED
Load Pres-
sure Sensor
Piston Out of
Range Low
221 OFF ON • Boom Lift Down =
PREVENTED
Sensor Current < 3.5mA for
500mS
latched
• Boom Telescope
Out = PREVENTED
• Winch Up = PRE-
VENTED
Load Pres-
sure Sensor
Rod Out of
Range High
222 OFF ON • Boom Lift Down =
PREVENTED
Sensor Current > 22.0mA for
500mS
latched
• Boom Telescope
Out = PREVENTED
• Winch Up = PRE-
VENTED
Load Pres-
sure Sensor
Rod Out of
Range Low
223 OFF ON • Boom Lift Down =
PREVENTED
Sensor Current < 3.5mA for
500mS
latched
• Boom Telescope
Out = PREVENTED
• Winch Up = PRE-
VENTED