Crane Fault Codes 149 Section - 21
Operator’s - Manual # 99906363
HELP
MESSAGE DTC
STOP
ICON
WARN
ICON ACTION TRIGGER LATCH
Crane Horn
– Open
Circuit
23101 OFF OFF • No restrictions Open Circuit detected on
Horn output and Crane Power
Enable is O.
Unlatched
Note: This Fault will not be
detected due to not knowing
when a Horn is installed on
the Crane.
Crane Horn
– Short To
Battery
23102 OFF ON • No restrictions Short to Battery was detected
on Horn Output
Unlatched
Crane Horn
– Short To
Ground
23103 OFF ON • Disable Output Short to Ground was detect-
ed on Horn Output
Latched
Crane Boom
Tip Light –
Open Circuit
23104 OFF ON • No restrictions Open Circuit detected on
Boom Tip Light Output
Unlatched
Vehicle must be congured
to have Boom Tip Lights
installed.
Crane Boom
Tip Light
– Short To
Battery
23105 OFF ON • No restrictions Short to Battery detected on
Boom Tip Light Output
Unlatched
Vehicle must be congured
to have Boom Tip Lights
installed.
Crane Boom
Tip Light
– Short To
Ground
23106 OFF ON • Disable Output Short to Ground was detect-
ed on Boom Tip Light Output
Latched
Vehicle must be congured
to have Boom Tip Lights
installed.
Boom Lift
Up – Open
Circuit
23107 OFF ON • No restrictions Open Circuit detected on
Boom Lift Up Output.
Unlatched
Boom Lift Up
– Short To
Battery
23108 OFF ON • Disable Lift UP/
Down Output and
turn o Low Side
Drive
Short to Battery detected on
Boom Lift Up Output
Latched
Boom Lift Up
– Short To
Ground
23109 OFF ON • Disable Output Short to Ground was detect-
ed on Boom Lift Up Output
Latched
Boom Lift
Down –
Open Circuit
23110 OFF ON • No restrictions Open Circuit detected on
Boom Lift Down Output.
Unlatched
Boom Lift
Down –
Short To
Battery
23111 OFF ON • Disable Lift UP/
Down Output and
turn o Low Side
Drive
Short to Battery detected on
Boom Lift Down Output
Latched
Boom Lift
Down –
Short To
Ground
23112 OFF ON • Disable Output Short to Ground was detect-
ed on Boom Lift Down Output
Latched