Crane Fault Codes 150 Section - 21
Operator’s - Manual # 99906363
HELP
MESSAGE DTC
STOP
ICON
WARN
ICON ACTION TRIGGER LATCH
Boom Tele-
scope Out –
Open Circuit
23113 OFF ON • No restrictions Open Circuit detected on
Boom Tele Out Output.
Unlatched
Boom Tele-
scope Out
– Short To
Battery
23114 OFF ON • Disable Telescope
In/Out Output and
turn o Low Side
Drive
Short to Battery detected on
Boom Tele Out Output
Latched
Boom Tele-
scope Out
– Short To
Ground
23115 OFF ON • Disable Output Short to Ground was detect-
ed on Boom Tele Out Output
Latched
Boom Tele-
scope In –
Open Circuit
23116 OFF ON • No restrictions Open Circuit detected on
Boom Tele In Output.
Unlatched
Boom
Telescope
In – Short To
Battery
23117 OFF ON • Disable Telescope
In/Out Output and
turn o Low Side
Drive
Short to Battery detected on
Boom Tele In Output
Latched
Boom
Telescope
In – Short To
Ground
23118 OFF ON • Disable Output Short to Ground was detect-
ed on Boom Tele In Output
Latched
Winch Out –
Open Circuit
23119 OFF ON • No restrictions Open Circuit detected on
Winch Out Output.
Unlatched
Winch Out
– Short To
Battery
23120 OFF ON • Disable Winch In/
Out Output and turn
o Low Side Drive
Short to Battery detected on
Winch Out Output
Latched
Winch Out
– Short To
Ground
23121 OFF ON • Disable Output Short to Ground was detect-
ed on Winch Out Output
Latched
Winch In –
Open Circuit
23122 OFF ON • No restrictions Open Circuit detected on
Winch In Output.
Unlatched
Winch In
– Short To
Battery
23123 OFF ON • Disable Winch In/
Out Output and turn
o Low Side Drive
Short to Battery detected on
Winch In Output
Latched
Winch In
– Short To
Ground
23124 OFF ON • Disable Output Short to Ground was detect-
ed on Winch In Output
Latched
Crane Ro-
tate Clock-
wise – Open
Circuit
23125 OFF ON • No restrictions Open Circuit detected on
Crane Rotate Clockwise
Output.
Unlatched
Crane Ro-
tate Clock-
wise – Short
To Bat tery
23126 OFF ON • Disable Rotate CW/
CCW Output and
turn o Low Side
Drive
Short to Battery detected
on Crane Rotate Clockwise
Output
Latched
Crane Ro-
tate Clock-
wise – Short
To Ground
23127 OFF ON • Disable Output Short to Ground was detect-
ed on Crane Rotate Clock-
wise Output
Latched