Crane Fault Codes 151 Section - 21
Operator’s - Manual # 99906363
HELP
MESSAGE DTC
STOP
ICON
WARN
ICON ACTION TRIGGER LATCH
Crane Ro-
tate Counter
Clockwise –
Open Circuit
23128 OFF ON • No restrictions Open Circuit detected on
Crane Rotate Counter Clock-
wise Output.
Unlatched
Crane Ro-
tate Counter
Clockwise
– Short To
Battery
23129 OFF ON • Disable Rotate CW/
CCW Output and
turn o󰀨 Low Side
Drive
Short to Battery detected on
Crane Rotate Counter Clock-
wise Output
Latched
Crane Ro-
tate Counter
Clockwise
– Short To
Ground
23130 OFF ON • Disable Output Short to Ground was detect-
ed on Crane Rotate Counter
Clockwise Output
Latched
Crane
Speed Con-
trol Valve –
Open Circuit
23131 OFF ON • No restrictions Open Circuit detected on
Crane Speed Control Valve
Output.
Unlatched
• Crane Functions =
PREVENTED
Crane must be congured as
a Single Proportional hydrau-
lic system.
Crane
Speed Con-
trol Valve
– Short to
Battery
23132 OFF ON • Disable Output and
turn o󰀨 Low Side
Drive
Short to Battery detected on
Crane Speed Control Valve
Output
Latched
• Crane Functions =
PREVENTED
Crane must be congured as
a Single Proportional hydrau-
lic system.
Crane
Speed Con-
trol Valve
– Short To
Ground
23133 OFF ON • Disable Output Short to Ground was detect-
ed on Crane Speed Control
Valve Output
Latched
• Crane Functions =
PREVENTED
Crane must be congured as
a Single Proportional hydrau-
lic system.
Crane En-
gine Start –
Open Circuit
23134 OFF ON • No restrictions Open Circuit detected on
Engine Start Output
Latched
Note: This Fault will not be
detected Pull Up resister
removed.
Crane En-
gine Start
– Short To
Battery
23135 OFF ON • Engine Start/Stop =
PREVENTED
Short to Battery detected on
Engine Start Output
Unlatched
Crane En-
gine Start
– Short To
Ground
23136 OFF ON • Disable Output Short to Ground was detect-
ed on Engine Start Output
Latched
Crane En-
gine Stop –
Open Circuit
23137 OFF ON • No restrictions Open Circuit detected on
Engine Stop Output
Latched
Note: This Fault will not be
detected Pull Up resister
removed.