Crane Fault Codes 152 Section - 21
Operator’s - Manual # 99906363
HELP
MESSAGE DTC
STOP
ICON
WARN
ICON ACTION TRIGGER LATCH
Crane
Engine Stop
– Short To
Battery
23138 OFF ON • Engine Start/Stop =
PREVENTED
Short to Battery detected on
Engine Stop Output
Unlatched
Crane
Engine Stop
– Short To
Ground
23139 OFF ON • Disable Output Short to Ground was detect-
ed on Engine Stop Output
Latched
Crane En-
gine Speed
1 – Open
Circuit
23140 OFF ON • No restrictions Open Circuit detected on
Engine Speed 1 Output
Latched
Note: This Fault will not be
detected Pull Up resister
removed.
Crane En-
gine Speed
1 – Short To
Battery
23141 OFF ON • No restrictions Short to Battery detected on
Engine Speed 1 Output
Unlatched
Crane En-
gine Speed
1– Short To
Ground
23142 OFF ON • Disable Output Short to Ground was detect-
ed on Engine Speed 1 Output
Latched
Crane En-
gine Speed
2 – Open
Circuit
23143 OFF ON • No restrictions Open Circuit detected on
Engine Speed 2 Output.
Latched
Vehicle must be congured
to have dual engine RPM
speeds.
Note: This Fault will not be
detected Pull Up resister
removed.
Crane En-
gine Speed
2 – Short To
Battery
23144 OFF ON • No restrictions Short to Battery detected on
Engine Speed 2 Output.
Unlatched
Crane En-
gine Speed
2– Short To
Ground
23145 OFF ON • Disable Output Short to Ground was de-
tected on Engine Speed 2
Output.
Latched
Crane Dump
Valve –
Short To
Battery
23146 OFF ON • No restrictions Short to Battery detected on
Dump Valve Output.
Unlatched
Crane Dump
Valve –
Short To
Ground
23147 OFF ON • Disable Output Short to Ground was detect-
ed on Dump Valve Output.
Unlatched
Crane Hour
meter –
Short To
Battery
23149 OFF ON • No restrictions Short to Battery detected on
Crane Hour Meter Output.