Crane Fault Codes 153 Section - 21
Operator’s - Manual # 99906363
HELP
MESSAGE DTC
STOP
ICON
WARN
ICON ACTION TRIGGER LATCH
Crane Hour
meter –
Short To
Ground
23150 OFF ON • Disable Output Short to Ground was de-
tected on Crane Hour Meter
Output.
Latched
Winch Brake
– Open
Circuit
23151 OFF ON • Winch Function
Disabled
Open Circuit detected on
Winch Brake Output.
Unlatched
Winch Brake
– Short To
Battery
23152 OFF ON • Winch Function
Disabled
Short to Battery detected on
Winch Brake Output
Unlatched
Winch Brake
– Short To
Ground
23153 OFF ON • Winch Function
Disabled
Short to Ground was detect-
ed on Winch Brake Output
Latched
• Disable Output
Crane Air
Compressor
– Short To
Battery
23154 OFF ON • No restrictions Short to Battery detected on
Air Compressor Output
Unlatched
Crane Air
Compressor
– Short To
Ground
23155 OFF ON • Disable Output Short to Ground was detect-
ed on Air Compressor Output
Latched
Crane Func-
tion Selector
– Short To
Battery
23156 OFF ON • No restrictions Short to Battery detected on
Function Selector Output
Unlatched
Crane Func-
tion Selector
– Short To
Ground
23157 OFF ON • Disable Output Short to Ground was de-
tected on Function Selector
Output
Latched
Snubbing
Indicator
– Short To
Battery
23158 OFF ON • No restrictions Short to Battery detected on
Snubbing Indicator Output
Unlatched
Snubbing
Indicator
– Short To
Ground
23159 OFF ON • Disable Output Short to Ground was detect-
ed on Snubbing Indicator
Output
Latched
Overload
Indicator
– Short To
Battery
23160 OFF ON • No restrictions Short to Battery detected on
Overload Indicator Output
Unlatched
Overload
Indicator
– Short To
Ground
23161 OFF ON • Disable Output Short to Ground was detect-
ed on Overload Indicator
Output
Latched
LMI Green
Indicator
– Short To
Battery
23162 OFF ON • No restrictions Short to Battery detected on
LMI Green Indicator Output
Unlatched