Crane Fault Codes 154 Section - 21
Operator’s - Manual # 99906363
HELP
MESSAGE DTC
STOP
ICON
WARN
ICON ACTION TRIGGER LATCH
LMI Green
Indicator
– Short To
Ground
23163 OFF ON • Disable Output Short to Ground was detect-
ed on LMI Green Indicator
Output
Latched
Remote
Base Power
Enable –
Short To
Battery
23164 OFF ON • No restrictions Short to Battery detected on
Remote Base Power Enable
Output
Unlatched
Remote
Base Power
Enable –
Short To
Ground
23165 OFF ON • Disable Output Short to Ground was detect-
ed on Remote Base Power
Enable Output
Latched
Length Sen-
sor – Not
Calibrated
241 OFF ON • Length sensor =
UNHEALTHY
When the Length sensors is
congured and Calibration
values are invalid.
Unlatched
Boom Angle
Sensor – Not
Calibrated
242 OFF ON • Angle sensor =
UNHEALTHY
When the Angle sensors is
congured and Calibration
values are invalid.
Unlatched
Rotation
Sensor – Not
Calibrated
243 OFF ON • Rotation sensor =
UNHEALTHY
When the Rotation sensors
is congured and Calibration
values are invalid.
Unlatched
CAN Bus
Failure –
Display
662 OFF ON • Crane Recovery =
PREVENTED
The Crane Module failed to
receive messages from the
Display. Check wiring at the
Display.
Latched
• Functions Request Mes-
sage – (0x0B) not received
for 30000mS upon Startup
and 250mS thereafter.
Crane needs to be congured
as a Hydraulic Gen 2 system
CAN Bus
Failure –
Crane Re-
mote Control
Receiver
Module
664 OFF ON • Crane Functions =
PREVENTED can
still use Crane Re-
covery if equipped
The Remote Base Power
Enable has been on for 2500
msec and The Crane Module
failed to receive messages
from the Crane Remote Con-
trol Receiver Module for 250
msec. Check wiring at the
Remote I/O Module.
Latched
CAN Bus
Failure –
Crane Re-
mote Control
Module
665 OFF ON • Crane Functions =
PREVENTED can
still use Crane Re-
covery if equipped
The Crane Module failed
to receive messages from
the Crane Remote Control
Module when operating in
tethered mode. Check wiring
at the Remote I/O Module.
Latched

Table of Contents