5
Place the two probes of the multimeter on the eye terminals B without disconnecting them and check
continuity with a digital multimeter.
If the above conditions are respected, the thermal cutout can also be checked without
disconnecting the terminals from the main machine wiring. No continuity is in fact present in the
machine wiring, therefore the only continuity is attributable to the thermal cutout.
6
If the display of the multimeter moves from the initial position, continuity is present and the thermal cutout G7
is functioning correctly, see previous paragraph.
7
If the multimeter display does not move from the initial position, the thermal cutout G7 must be replaced with
a new one. For replacement see the previous paragraph.
B
B
PHOTO 317
G7
PHOTO 318