B2.2 Checking squeegee actuator operation manually
Checks
1
Make sure the batteries on the machine are charged (36 V ± 1 V).
2
Obtain a clamp meter able to read up to 200 A (amps), see photograph below.
3
Obtain two wires A1 - A2 with different colours (see photograph below) with plugs compatible with the
terminals of the connector B1.
4
Move the machine to the tank draining area and completely empty both tanks.
5
Move the machine onto a flat dry area of floor.
6
Switch the machine off by turning the ignition key C to "0" and press the pedal D to put the parking brake on.
7
Unscrew the knob E and lift both tanks to access the actuator connector G.
PHOTO 188
E
C
D
PHOTO 187
A
B1
A2
A1
PHOTO 186