PLDC01938
REVISION 00
01/06/2011
TECHNICAL DEPT.
Stavale
- date 05/09/2011
86/195
21
Compare the values noted with those in the table below. If the values are within the table, the actuator is
working correctly and there are no mechanical impediments to its operation.
22
If the measurements do not correspond to those specified, but are higher:
22a
Check that the squeegee mount is not distorted in such a way that moving it requires more force than
normal and that the squeegee mount joints are not excessively stiff.
22b
Release the rod E1 of the actuator E from the squeegee mount and check manually that it turns easily and
smoothly.
22c
Still with the rod E1 released from the squeegee mount, check current draw, remembering to hold the rod
E1 with one hand to prevent it rotating.
22d
If the above points are OK, replace the actuator with a new one.
Draw A (amps) Min Max
During lowering 1.2 A 3.0 A
During raising 0.8 A 3.0 A
PHOTO 185
E1
E