Chapter 3 - page 9
Operator’s manual ASTRONAUT
M-HE.002.1003
There is a possibility for generating an alarm if an insufficient amount of
cleaning agent is measured. This is determined by the MC or MQC system.
It is strongly recommended to always opt for "yes" in this screen.
An alarm is generated if the actual time for filling the cleaning tank takes
longer than the adjusted time.
An alarm is generated if filling of the cleaning tank exceeds the adjusted time.
If the alarm is not reset after 30 minutes, a cleaning with cold water will be
initiated.
If the actual time between two milkings exceeds the adjusted time, the robot
will generate an alarm.
If the number of failed milkings exceeds the adjusted number of failures, the
robot will generate an alarm. The failed milkings must be successive and
relate to different cows.
After opening the front gate to release the cow from the box, the movement
inductor (where fitted) is activated as soon as the adjusted time has lapsed.
The intensity of the expel shock starts at a very low level, but increases
gradually.
If "Priority for feeding" is on, the cow is kept in the box until the ration
available at that time has been consumed.
yes
Alarm no
Astri-cid: Astri-lin
no
Alarm time fill
15 min
Alarm time heater
120 min
Alarm after:
240 min
robot not in operat.
Alarm after:
failed milking:
3
Shock on
10 sec after:
exit gate open
yes
Priority
for feeding:
no