EasyManua.ls Logo

Lenovo ThinkSystem SR630 V3 - Page 406

Lenovo ThinkSystem SR630 V3
508 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Figure 334. Cable routing for 6 SAS/SATA drives and 2 AnyBay drives and 2 NVMe front drive bays with an 8i or 16i CFF
RAID adapter (Gen 3 or Gen 4)
Table 141. Mapping between one front SAS/SATA backplane and a CFF RAID adapter
Backplane/adapter
From To
Front BP (SAS)
1 SAS 0 1 C0
2 SAS 1 2 C1
Front BP (NVMe)
3 NVMe 2–3, 0–1
3 PCIe 1, 2
CFF RAID adapter
4 MB input
4 PCIe 3
10 x 2.5'' SAS/SATA
See this section to understand the cable routing of 10 front SAS/SATA drives with the 6 x 2.5'' SAS/SATA + 4
x 2.5'' AnyBay backplane installed.
396
ThinkSystem SR630 V3 User Guide

Table of Contents

Other manuals for Lenovo ThinkSystem SR630 V3

Related product manuals