8400 StateLine C | Reference manual
Technology applications
TA "Actuating drive speed"
310 L Firmware ≤ 11.00 - DMS 8.0 EN - 10/2011
7.2.3.8 MCI
Process data assignment for fieldbus communication
( 311)
Connection Assignment Connection Assignment
X101/NC-NO LA_NCtrl.bDriveFail
X4/RFR LA_NCtrl.bFailReset X3/A1U LA_NCtrl.nAuxSetValue_a *
X4/DI1 LA_NCtrl.bSetQuickStop X3/A1I -
X4/DI2 - X3/O1U LA_NCtrl.nMotorSpeedAct_a *
X4/DI3 - * 10 V ≡ 100 % reference speed (C00011
)
X4/DI4 - X4/DO1 LA_NCtrl.bDriveReady
Note!
• You must set the setpoint arithmetic in C00190 to "1: NOut = NSet + NAdd"
so that the additional speed setpoint selected via the analog input A1U has
an additive effect.
• The "manual jog" function via digital terminals is being prepared!