Firmware 11.00 - DMS 8.0 EN - 10/2011 L 309
8400 StateLine C | Reference manual
Technology applications
TA "Actuating drive speed"
7.2.3.7 CAN
Process data assignment for fieldbus communication
( 311)
Connection Assignment Connection Assignment
X101/NC-NO LA_NCtrl.bDriveFail
X4/RFR LA_NCtrl.bFailReset X3/A1U LA_NCtrl.nAuxSetValue_a *
X4/DI1 LA_NCtrl.bSetQuickStop X3/A1I -
X4/DI2 - X3/O1U LA_NCtrl.nMotorSpeedAct_a *
X4/DI3 - * 10 V 100 % reference speed (C00011
)
X4/DI4 - X4/DO1 LA_NCtrl.bDriveReady
Note!
You must set the setpoint arithmetic in C00190 to "1: NOut = NSet + NAdd"
so that the additional speed setpoint selected via the analog input A1U has
an additive effect.
The "manual jog" function via digital terminals is being prepared!
+
=
++
X4
DI3
DI2
DI4
GIO
24I
DI1
RFR
24E
+
X3
AR
A1U
GA
A1I
DO1
O1U
LP_CanIn1
LP_CanOut1
wCtrl
wIn2
wIn3
DriveControl
MainSetValue
-
wState
wOut2
wOut3
DriveControlStatus
MotorSpeedAct
MotorSpeedSet
wOut4
-
COM
NC
NO
X101
CG
CL
CH
X1
Controller enable / reset error
Quickstop
External
supply
24 V DC
DriveReady
Additional speed setpoint
Actual speed value
DriveFail