8400 StateLine C | Reference manual
Technology applications
TA "Switch-off positioning"
336 L Firmware ≤ 11.00 - DMS 8.0 EN - 10/2011
7.3.3.7 CAN
Process data assignment for fieldbus communication
( 338)
Connection Assignment Connection Assignment
X101/NC-NO LA_SwitchPos.bDriveFail
X4/RFR LA_SwitchPos: bFailReset X3/A1U LA_SwitchPos.nAuxSetValue_a *
X4/DI1 LA_SwitchPos: bJogCtrlStop1 X3/A1I -
X4/DI2 LA_SwitchPos: bJogCtrlSlowDown1 X3/O1U -
X4/DI3 LA_SwitchPos: bJogCtrlStop2 * 10 V ≡ 100 % reference speed (C00011
)
X4/DI4 LA_SwitchPos: bJogCtrlSlowDown2 X4/DO1 LA_SwitchPos.bDriveReady
Note!
You must set the setpoint arithmetic in C00190 to "1: NOut = NSet + NAdd" so
that the additional speed setpoint selected via the analog input A1U has an
additive effect.
+
=
++
X4
DI3
DI2
DI4
GIO
24I
DI1
RFR
24E
+
X3
AR
A1U
GA
A1I
DO1
O1U
-
COM
NC
NO
X101
LP_CanIn1
LP_CanOut1
wCtrl
wIn2
wIn3
DriveControl
MainSetValue
-
wState
wOut2
wOut3
DriveControlStatus
MotorSpeedAct
GPSignalOut1
wOut4
-
CG
CL
CH
X1
Stop function 2
Stop function 1
Selection of pre-switch off 1
Selection of pre-switch off 2
External
supply
24 V DC
Additional speed setpoint
Controller enable / reset error