8.4.2.2 Functional settings
The following bit coded functional settings for the holding brake control can be made in
C02582
:
Bit Option Info
Bit 0 bMBrakeReleaseOut invert. Activation of inverted control
•"1" Inverted logic of trigger signal for holding brake control
switching element
Bit 1 Horizontal brake protection Brake response in case of pulse inhibit
•"1" In the case of a pulse inhibit, the actual speed value is
monitored which must reach the "Close" threshold value to cause
the holding brake to be applied.
Note:
This function is only active if bit 3 (horizontal/winding
technology) is set as well. The function is used in order that, when
the controller is inhibited, the holding brake of a drive with
horizontal traverse path does not wear out during rotation.
With vertical motion (bit 3 = 0), this function is not active.
Especially with hoists and activated pulse inhibit of the controller,
an immediate application of the brake is essential for safety-
related reasons!
Bit 2 with hoist inv. feedfwd. control Direction of feedforward control with vertical/hoist technology:
•"0" Positive direction
•"1" Negative direction
Note:
Reversal (Ccw) is then considered.
Bit 3 Horizontal application Direction of movement of the axis
•"0" The axis performs vertical movements. Gravitational
acceleration causes movements.
•"1" The direction of the axis is horizontal or rotary. The
gravitational acceleration does not cause any movement.
Bit 4 Feedforward control C2581
(from version 11.00.00)
Selection of the feedforward control value
•"0" Automatic selection.
The torque saved at the last stop is used.
•"1" Manual selection.
bMBrakeStartValue2 = FALSE: The feedforward control value 1
set in C02581/4
is used.
bMBrakeStartValue2 = TRUE: The feedforward control value set
in C02581/5
is used.
Bit 5 Feedback monitoring
(from version 11.00.00)
Activation of status monitoring
•"1" The bMBrakeApplied input for status detection of the brake
(via a switching contact at the brake) is monitored after the
waiting time set in C02589/3
has expired.
Bit 6 Sync ramp L_NSet_1
(from version 11.00.00)
Selection of the ramp time for the synchronisation process to
setpoint speed after the brake opening time has elapsed
Revised behaviour from version 11.00.00:
•"1" The ramp time of the effective acceleration of the ramp
function generator (L_NSet_1
) is used (Lenze setting).
•"0" As before, the ramp time set in C02610/1
is used.
Note:
The changeover can be dynamically both via the ramp parameter
and via bit 6.
Bit 7 Reserved