Diagnostics & error management
Error messages of the operating system
dH09: EEPROM power section [xx.0400.00009]
dH10: Fan failure [xx.0400.00016]
dH68: Adjustment data error CU [xx.0400.00104]
dH69: Adjustment data error BU [xx.0400.00105]
US01: User error 1 [xx.0980.00001]
US02: User error 2 [xx.0981.00002]
Response (Lenze setting printed in bold)
0: No Reaction : 1: Fault 2: Trouble 3: TroubleQuickStop 4: WarningLocked 5: Warning 6: Information
Cause Remedy
Device error Consultation with Lenze required.
Response (Lenze setting printed in bold) Setting: C00566 (; Adjustable response)
; 0: No Reaction ; 1: Fault 2: Trouble 3: TroubleQuickStop 4: WarningLocked : 5: Warning 6: Information
Cause Remedy
The device fan has failed.
Possible causes:
• The short-circuit check of the fan connection has
tripped.
• The speed monitoring of the fan has tripped.
• Check the fan for short-circuit.
•Clean the fan.
Response (Lenze setting printed in bold)
0: No Reaction : 1: Fault 2: Trouble 3: TroubleQuickStop 4: WarningLocked 5: Warning 6: Information
Cause Remedy
Device error Consultation with Lenze required.
Response (Lenze setting printed in bold)
0: No Reaction : 1: Fault 2: Trouble 3: TroubleQuickStop 4: WarningLocked 5: Warning 6: Information
Cause Remedy
Device error Consultation with Lenze required.
Response (Lenze setting printed in bold) Setting: C00581/1 (; Adjustable response)
: 0: No Reaction ; 1: Fault ; 2: Trouble ; 3: TroubleQuickStop ; 4: WarningLocked ; 5: Warning ; 6: Information
Cause Remedy
User error 1 has been tripped via the bSetError1 input of
the LS_SetError_1
system block.
User-defined.
Response (Lenze setting printed in bold) Setting: C00581/2 (; Adjustable response)
: 0: No Reaction ; 1: Fault ; 2: Trouble ; 3: TroubleQuickStop ; 4: WarningLocked ; 5: Warning ; 6: Information
Cause Remedy
User error 2 has been tripped via the bSetError2 input of
the LS_SetError_1
system block.
User-defined.