Address Designaon Default seng Data type Factor A M
0x5051:053 Manual jog jerk 100.00 mm/s³ I32 100 -
0x5051:064 Eecve velocity for diameter
calculaon x.xxxx mm/s (Read only) I32 10000 X
0x5051:065 Start diameter source Parameter [0] I16 -
0x5051:066 Start diameter 100.0000 mm I32 10000 -
0x5051:067 External start diameter x.xxxx mm (Read only) I32 10000 X
0x5051:068 Start diameter adapted via characterisc curve x.xxxx mm (Read only) I32 10000 X
0x5051:069 Source of line velocity for diameter calculaon 0 BOOLEAN -
0x5051:070 Number of revoluons for standard diameter calcu-
laon
1.00 rev I32 100 -
0x5051:071 Number of revoluons for fast diameter calculaon 0.10 rev I32 100 -
0x5051:072 Web break detecon window size 10.00 % I32 100 -
0x5051:073 Web break monitoring mode Dancer in limit posion [1] U16 -
0x5051:074 Filter me actual diameter 0.050 s I32 1000 -
0x5051:075 Set diameter x.xxxx mm (Read only) I32 10000 X
0x5051:076,
078, 080, 082,
084, 086, 088,
090, 092
X value for diameter adapon 0.0000 mm I32 10000 -
0x5051:077,
079, 081, 083,
085, 087, 089,
091, 093
Y value for diameter adapon 0.0000 mm I32 10000 -
0x5051:096 Actual diameter x.xxxx mm (Read only) I32 10000 X
0x5051:097 Max. permissible winding velocity 1.00 rev/s I32 100 -
0x5051:098 Vp of diameter idencaon 100.00 % I32 100 -
0x5051:099 Diameter idencaon velocity 100.0000 mm/s I32 10000 -
0x5051:100 Diameter idencaon
acceleraon 2000.00 mm/s² I32 100 -
0x5051:101 Diameter idencaon deceleraon 2000.00 mm/s² I32 100 -
0x5051:102 Diameter idencaon jerk 2000.00 mm/s³ I32 100 -
0x5051:103 Required calculaon cycles for diameter idenca-
on
2 U16 1 -
0x5051:104 Max. dancer posion diameter idencaon 50.00 % I32 100 -
0x5051:110 Actual moment of inera - (Read only) I32 1 X
0x5051:111 Constant moment of inera 1.0000000000 I32 1 -
0x5051:112 Max. moment of inera 10.0000000000 I32 1 -
0x5051:113 Moment of
inera idencaon - velocity lter me 0.010 s I32 1000 -
0x5051:114 Moment of inera idencaon - torque lter me 0.005 s I32 1000 -
0x5051:115 Moment of inera idencaon - max. velocity 20.00 % I32 100 -
0x5051:116 Moment of inera idencaon - max. torque 20.00 % I32 100 -
0x5051:117 Idenfy moment of inera 0 BOOLEAN -
0x5051:118 Measured moment of inera - (Read only) I32 1 X
0x5051:119 Moment of inera adapon 100.00 % I32 100 -
0x5051:120 Filter me acceleraon
compensaon 0.005 s I32 1000 -
0x5051:121 Acceleraon torque dead me 0.10 Nm I32 100 -
0x5051:122 Evaluaon acceleraon torque posive 105.00 % I32 100 -
0x5051:123 Evaluaon acceleraon torque negave 95.00 % I32 100 -
0x5051:124 Acceleraon compensaon set torque x.xx Nm (Read only) I32 100 X
0x5051:125 Eecve acceleraon compensaon set torque x.xx % (Read only) I32 100 X
0x5052:169 Teached dancer upper limit posion - (Read only) I32 1 X
0x5052:170 Teached dancer lower limit posion - (Read only) I32 1 X
0x5052:171 Upper dancer limit posion 10000.0000000000 I32 1 -
0x5052:172 Lower dancer limit posion 0.0000000000 I32 1 -
0x5052:173 Dancer limit posion source 0 BOOLEAN -
0x5052:174 Source of dancer control inuence External [0] I16 -
0x5052:175 Set dancer control inuence 0.00 % I32 100 -
* Default seng depending on the size.
Appendix
P
arameter aribute list
487