Address Designaon Default seng Data type Factor A M
0x5021:155 System bus
diagnoscs: Time stamp (input value) x ns (Read only) U32 1 X
0x5021:156 System bus diagnoscs: Input data word 6 - (Read only) U32 1 X
0x5021:157 System bus diagnoscs: Input data word 7 - (Read only) U32 1 X
0x5021:160 System bus diagnoscs: Cycle length (output value) - (Read only) I32 10000 X
0x5021:161 System bus diagnoscs: Posion (output value) - (Read only) I32 10000 X
0x5021:162 System bus diagnoscs: Velocity (output value) - (Read only) I32 10000 X
0x5021:163 System bus diagnoscs: Acceleraon (output value) - (Read only) I32 100 X
0x5021:164 System bus diagnoscs: Torque (output value) x.xx Nm (Read only) I32 100 X
0x5021:165 System bus diagnoscs: Time stamp (output value) x ns (Read only) U32 1 X
0x5021:167 System bus diagnoscs: Output data word 7 - (Read only) U32 1 X
0x5021:168 System bus diagnoscs: Actual diameter (output
value)
x.xxxx mm (Read only) I32 10000 X
0x5050:001 Simulaon of control signals 0x00 U8 H
0x5050:006 Display value 1 Actual dancer posion [7] I16 -
0x5050:007 Display value 2 Master speed limit [8] I16 -
0x5050:010 Control signals 0x00000000 U32 H
0x5050:011 Set diameter (control word 2) 0.0000 mm I32 10000 -
0x5050:012 Set velocity (control word 2) 0.0000 mm/s I32 10000 -
0x5050:016 Control word 6 0 U32 1 -
0x5050:017 Control word 7 0 U32 1 -
0x5050:023 Set dancer posion (input value) 0.00 % I32 100 -
0x5050:024 Dancer control inuence (control word 5) 0.00 % I32 100 -
0x5050:025 Actual dancer posion (input value) 0.00 I32 100 -
0x5050:101 Simulaon of status signals 0x00 U8 HX
0x5050:110 Status signals 0x00000000 U32 H
0x5050:111 Status signals limiter 0x00000000 U32 HX
0x5050:112 Actual velocity (status word 3) 0.0000 I32 10000 X
0x5050:113 Actual
posion (status word 4) 0.0000 I32 10000 X
0x5050:114 Error code (status word 5) 0 U32 1 X
0x5050:115 Actual diameter (status word 6) 0.0000 mm I32 10000 X
0x5050:116 Display value 1 0 U32 1 X
0x5050:117 Display value 2 0 U32 1 X
0x5051:001 Technology applicaon state - (Read only) I16 X
0x5051:007 Evaluaon line velocity - numerator 1.0000000000 I32 1 -
0x5051:008 Evaluaon line velocity - denominator 1.0000000000 I32 1 -
0x5051:009 Actual line velocity x.xxxx mm/s (Read only) I32 10000 X
0x5051:010 Winder reference speed at dmin x.xx rev/s (Read only) I32 100 X
0x5051:011 Winding direcon with line velocity > 0 0 BOOLEAN -
0x5051:012 Line velocity reference 1000.0000 mm/s I32 10000 -
0x5051:013 Min. line velocity 1.0000 mm/s I32 10000 -
0x5051:016 Min. reel diameter 50.0000 mm I32 10000 -
0x5051:017 Max. reel diameter 180.0000 mm I32 10000 -
0x5051:020 Acceleraon to synchronize to line velocity 1.00 mm/s² I32 100 -
0x5051:021 Deceleraon to synchronize to line velocity 1.00 mm/s² I32 100 -
0x5051:029 Speed controller gain adapon 100.00 % I32 100 -
0x5051:030 Speed controller adapon mode Vp
adapon = d² [0] I16 -
0x5051:031 Speed control adapon min. value 20.00 % I32 100 -
0x5051:032 Speed controller actual gain x.xx % (Read only) I32 100 X
0x5051:033 Eecve set speed x.xx rev/s (Read only) I32 100 X
0x5051:037 Winder speed x.xx rev/s (Read only) I32 100 X
0x5051:038 Master speed limit x.xxxx mm/s (Read only) I32 10000 X
0x5051:050 Manual jog velocity 10.0000 mm/s I32 10000 -
0x5051:051 Manual jog acceleraon 1.00 mm/s² I32 100 -
0x5051:052 Manual jog deceleraon 1.00 mm/s² I32 100 -
* Default seng depending on the size.
Appendix
P
arameter aribute list
486