Processor ID
This is a 16‑digit hexadecimal value representing the ID of the processor on the controller card.
Engine Setting [x]
These settings are used by Engine code ECs to fix field problems. The value of [x] is any value from 1 to 16.
Edge to Edge
When set to On, this shifts all four margins (top, bottom, left, and right) to the physical edge of the page (printable area
of a supported paper size).
Par 1 Strobe Adj
This enables the user to adjust the amount of time the strobe is sampled to determine if valid data is available on the
parallel port.
Each time this value is increased by 1, the strobe is sampled 50 ns longer. Each time this value is decreased by 1, the
strobe is sampled 50 ns less. When the value of this setting is 0, the factory default value is used to determine the
amount of time the strobe is sampled.
Available options: ‑4 to 1
EP Setup
EP Defaults
This setting restores each printer setting listed in EP setup to its factory default value. Sometimes this is used to help
correct print quality problems.
To restore the EP defaults:
1 From the Diagnostics menu, navigate to:
EP Setup > EP Defaults
2 Select Restore.
Fuser Temp
This setting adjusts the fuser temperature to solve problems with paper curl on low grade paper and/or melting of
letterhead on some papers.
To adjust this setting:
1 From the Diagnostics menu, navigate to:
EP Setup > Fuser Temp
2 Press OK to save any changes.
Transfer Adjust
This setting controls the transfer roll algorithm.
4514-420, -430
Service menus
118