Table of Functions
157
Code
Comm.
Address
Name LCD Display Setting Range
Initial
value
Property*
V/F SL Ref.
10: 7.5 kW,
11: 11.0 kW
12: 15.0 kW,
13: 18.5 kW
14: 22.0 kW
15: 30.0 kW
16:37 kW
17:45.0 kW
18:55.0 kW
19:75 kW
20:90 kW
15 0h110F
Torque boost
options
Torque Boost
0
Manual
0: Manual X O X
1
Auto1
2
Auto2
16
1
0h1110
Forward
Torque boost
Fwd Boost 0.0-15.0(%) 2.0 X O X p.101
17
1
0h1111
Reverse
Torque boost
Rev Boost 0.0-15.0(%) 2.0 X O X p.101
18 0h1112
Base
frequency
Base Freq
30.00~400.00(
Hz)
[V/F, Slip
Compen]
40.00~120.00(
Hz)
[IM Sensorless]
30.00~180.00(
Hz)
[PM
Sensorless ]
60.00 X O I/P p.97
19 0h1113
Start
frequency
Start Freq
0.01-10.00(Hz)
0.50 X O I/P p.97
20 0h1114
Maximum
frequency
Max Freq
40.00~400.00(
Hz)
[V/F, Slip
Compen]
40.00~120.00(
Hz)
[IM Sensorless]
40.00~180.00(
Hz)
[PM
Sensorless ]
60.00 X O I/P p.108
1
Displayed when DRV-15 is set to 0 (Manual) or 2(Auto2)