Page #181 background imageLoading...
Page #181 background image
Table of Functions
169
Code
Comm.
Address
Name LCD Display Setting Range
Initial
Value
Property*
V/F SL Ref.
66 0h1342
Output contact
On/Off control
options
On/Off Ctrl
Src
0
None
0:Non
e
X O I/P -
1
V1
3
V2
4
I2
6
Pulse
67 0h1343
Output contact
On level
On-Ctrl Level
Output contact
off level- 100.00%
90.00 X O I/P -
68 0h1344
Output contact
Off level
Off-Ctrl Level
-100.00-output
contact on level
(%)
10.00 X O I/P -
70 0h1346
Safe operation
selection
Run En Mode
0
Always
Enable
0:Alwa
ys
Enable
X O I/P -
1
DI Dependent
71
18
0h1347
Safe operation
stop options
Run Dis Stop
0
Free-Run
0:Free-
Run
X O I/P -
1
Q-Stop
2
Q-Stop
Resume
72
18
0h1348
Safe operation
deceleration
time
Q-Stop Time 0.0-600.0(s) 5.0 O O I/P -
74
19
0h134A
Selection of
regeneration
evasion
function for
press
RegenAvd Sel
0
No
0:No X O I -
1 Yes
75
19
0h134B
Voltage level of
regeneration
evasion motion
for press
RegenAvd
Level
200 V : 300-400 V
350
X O I -
400 V : 600-800 V 700
76
20
0h134C
Compensation
frequency limit
of regeneration
evasion for
press
CompFreq
Limit
0.00- 10.00 Hz 1.00 X O I -
77
20
0h134D
Regeneration
evasion for
press P gain
RegenAvd
Pgain
0.0- 100.0% 50.0 O O I -
18
Displayed when ADV-70 is set to 1 (DI Dependent)
19
Displayed when DRV-09 (Control Mode) is not set to 6 (PM Sensorless).
20
Displayed when ADV-74 is set to 1 (Yes)