EasyManua.ls Logo

LSIS S100 - Page 180

LSIS S100
288 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
168
Table of Functions
Code
Comm.
Address
Name LCD Display Setting Range
Initial
Value
Property*
V/F SL Ref.
33
15
0h1321
Jump frequency
upper limit3
Jump Hi 3
Jump frequency
lower limit3-
Maximum
frequency(Hz)
35.00 O O I/P p.110
41
16
0h1329
Brake release
current
BR Rls Curr 0.0-180.0(%)
50.0 O O I/P -
42
16
0h132A
Brake release
delay time
BR Rls Dly 0.00-10.00(s)
1.00 X O I/P -
44
16
0h132C
Brake release
Forward
frequency
BR Rls Fwd Fr
0.00-Maximum
frequency(Hz)
1.00 X O I/P
-
45
16
0h132D
Brake release
Reverse
frequency
BR Rls Rev Fr
0.00-Maximum
frequency(Hz)
1.00 X O I/P -
46
16
0h132E
Brake engage
delay time
BR Eng Dly 0.00-10.00(s)
1.00 X O I/P -
47
16
0h132F
Brake engage
frequency
BR Eng Fr
0.00-Maximum
frequency(Hz)
2.00 X O I/P -
50 0h1332
Energy saving
operation
E-Save Mode
0
None
0:Non
e
X O X -
1
Manual
2
Auto
51
17
0h1333
Energy saving
level
Energy Save 0-30(%) 0 O O X -
60 0h133C
Acc/Dec time
transition
frequency
Xcel Change
Fr
0.00-Maximum
frequency(Hz)
0.00 X O I/P p.93
61 0h133D
Rotation count
speed gain
Load Spd
Gain
0.1~6000.0[%] 100.0 O O I/P -
62 0h133E
Rotation count
speed scale
Load Spd
Scale
0
x 1
0: x 1 O O I/P -
1
x 0.1
2
x 0.01
3
x 0.001
4
x 0.0001
63 0h133F
Rotation count
speed unit
Load Spd
Unit
0
Rpm
0: rpm O O I/P -
1
mpm
64 0h1340
Cooling fan
control
FAN Control
0
During Run
0:Duri
ng
Run
O O I/P -
1
Always ON
2
Temp Control
65 0h1341
Up/down
operation
frequency save
U/D Save
Mode
0
No
0:No O O I/P -
1 Yes
16
Displayed when either OUT-31 or OUT-33 is set to 35 (BR Control)
17
Displayed when ADV-50 is not set to 0 (None)

Table of Contents

Other manuals for LSIS S100

Related product manuals