Table of Functions
177
Code
Comm.
Address
Name LCD Display Setting Range
Initial
Value
Property*
V/F SL Ref.
1 Flying Start-2
2
Flying Start-
3
31
71 0h1447
Speed
search
operation
selection
Speed
Search
bit
0000- 1111
0000
X O I/P -
0001
Selection of
speed search
on
acceleration
0010
When starting
on
initialization
after fault trip
0100
When
restarting
after
instantaneous
power
interruption
1000
When starting
with power on
72
33
0h1448
Speed
search
reference
current
SS Sup-
Current
80-200(%) 150
O O I -
73
34
0h1449
Speed
search
proportion
al gain
SS P-Gain 0-9999
Flying
Start-1
: 100
O O I -
Flying
Start-2
: 600
35
74
34
0h144A
Speed
search
integral
gain
SS I-Gain 0-9999
Flying
Start-1
: 200
O O I -
Flying
Start-2
: 1000
33