Functional Principle, Technical Data
optoNCDT 2300
Model ILD2300- 2LL 10LL 20LL 50LL
Measuring range
1
mm
(inches)
2 / 2
(.08 / .08)
10 / 5
(.39 / .20)
20 / 10
(.79 / .39)
50 / 25
(1.97 / .99)
Start of measuring range
1
mm
(inches)
24 / 24
(.94 / .94)
30 / 35
(1.18 / 1.38)
40 / 50
(1.57 / 1.97)
45 / 70
(1.77 / 2.76)
Midrange
1
mm
(inches)
25 / 25
(.98 / .98)
35 / 37,5
(1.38 / 1.48)
50 / 55
(1.97 / 2.17)
70 / 82.5
(2.76 / 3.25)
End of measuring range
1
mm
(inches)
26 / 26
(1.02 / 1.02)
40 / 40
(1.57 / 1.57)
60 / 60
(2.36 / 2.36)
95 / 95
(3.74 / 3.74)
Measuring rate
7 adjustable stages: 49.14 kHz
2
/ 30 kHz / 20 kHz / 10 kHz / 5 kHz / 2. kHz / 1.5 kHz
Linearity
µm < ± 0.6 < ± 2 < ± 4 < ± 10
% FSO < ± 0.03 < ± 0.02
Resolution (at 20 kHz)
2
µm 0.03 0.15 0.3 0.8
Light spot diameter
(±10 %)
SMR, µm 85 x 240 120 x 405 185 x 485 350 x 320
MR, µm 24 x 280 35 x 585 55 x 700 70 x 960
EMR, µm 64 x 400 125 x 835 195 x 1200 300 x 1940
Light source Semiconductor laser < 1 mW, 670 nm (red); Class 2 acc. to IEC 60825-1: 2014
Permissible ambient light 10,000 lx … 40,000 lx
Power supply 24 VDC (11 ... 30 V); P < 3 W
Digital interface
RS422 (16 bit) / Ethernet / EtherCAT / PROFINET
4
/ EtherNet/IP
4
Analog output
4
4 … 20 mA / 0 … 5 V / 0 … 10 V / ± 5 V / ± 10 V
Temperature range Operation: 0 ... +50 °C (+32 °F up to +122 °F); storage: -20 ... +70 °C; (non-condensing)
Shock (IEC 60068-2-29) 15 g / 6 ms / 3 axes
Vibration (IEC 60068-2-6) 2 g / 20 ... 500 Hz
Protection class (DIN EN 60529) IP65
Housing size, material S, die-cast zinc
Weight approx. 550 g (incl. pigtail)
FSO = Full Scale Output, SMR = Start of measuring range, MMR = Mid of measuring range, EMR = End of measuring range; The specified data ap-
ply to white, diffuse reflecting surfaces (Micro-Epsilon reference ceramic for ILD sensors)
1) Second value is valid for a measuring rate of 49.14 kHz 3) Measuring rate of 20 kHz
2) Measuring rate of 49.14 kHz with reduced measuring range 4) Connection via interface module (see accessories)