PROTOCOL-SPECIFIC INFORMATION
229
9
Produced Data Word Offset
The value from the associated inverter register will populate this word offset of the produced data that is
to be sent to the controller. It is recommended to start at word offset 0.
Consumed Data Word Offset
The consumed data received from the controller at this word offset will contain the value to be written to
the associated inverter register. It is recommended to start at word offset 0.
Register
The inverter register (refer to section 4) associated with the word offset. For the Produced Data Word
object, enter a “status register to be monitored. For the Consumed Data Word object, enter a
“command” register that can be written.
Data Type
Each data word is fixed to 16-Bit Unsigned. This is equivalent to two bytes. The data word is transferred
in little endian format.