EasyManua.ls Logo

Mitsubishi 700 Series

Mitsubishi 700 Series
280 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
INVERTER SETTINGS
35
3
3.1 Network Setting
The network settings can optionally be set using the inverter parameters described in the Table 17. An
invalid parameter value will void the inverter network parameters and fallback to the network settings
created by the Configuration Studio or the default network settings (IP address = 192.168.16.100,
Subnet mask = 255.255.255.0, and Default gateway = 192.168.16.3). To avoid invalid configuration, it is
therefore recommended to use the configuration studio to modify the network settings. Please consult
with your network administrator for the proper settings of these fields.
Table 17: Inverter Network Parameters
Parameter
Number
Name
232
IP address (and default gateway address) most significant octet
233
IP address (and default gateway address) high octet
234
IP address low octet
235
IP address least significant octet
236
Subnet mask most significant octet
237
Subnet mask address high octet
238
Subnet mask address low octet
239
Subnet mask address least significant octet
888
Default gateway address low octet
889
Default gateway address least significant octet

Table of Contents

Related product manuals