REGISTER NUMBERING AND BEHAVIOR
57
4
4.10 Operation Mode Status Register
The operation mode status is register 101 and the bit-mapping is described in Table 20.
4.11 Alarm History Codes
The alarm history codes are listed in Table 23. The alarm codes are described in the inverter user
manual “List of alarm display” section.
Table 23: Alarm History Codes
Value
Code
Value
Code
Value
Code
Value
Code
Value
Code
0x00
No Alarm
0x51
E.UVT
0xB0
E.PE
0xC8
E.USB
0xDB
E.MB7
0x10
E.OC1
0x52
E.ILF
0xB1
E.PUE
0xD0
E.OS
0xD9
E.MB5
0x11
E.OC2
0x60
E.OLT
0xB2
E.RET
0xD1
E.OSD
0xDC
E.EP
0x12
E.OC3
0x70
E.BE
0xB3
E.PE2
0xD2
E.ECT
0xF1
E.1
0x20
E.OV1
0x80
E.GF
0xC0
E.CPU
0xD3
E.OD
0xF2
E.2
0x21
E.OV2
0x81
E.LF
0xC1
E.CTE
0xD5
E.MB1
0xF3
E.3
0x22
E.OV3
0x90
E.OHT
0xC2
E.P24
0xD6
E.MB2
0xF5
E.5
0x30
E.THT
0x91
E.PTC
0xC4
E.CDO
0xD7
E.MB3
0xF6
E.6
0x31
E.THM
0xA0
E.OPT
0xC5
E.IOH
0xD8
E.MB4
0xF7
E.7
0x40
E.FIN
0xA1
E.OP1
0xC6
E.SER
0xD9
E.MB5
0xFB
E.11
0x50
E.IPF
0xA3
E.OP3
0xC7
E.AIE
0xDA
E.MB6
0xFD
E.13

Table of Contents