PRE-OPERATION INSTRUCTIONS
26
Error (LED4)
LED Activity
Status
Note
Off Device Off or No Error
The inverter power is off or the EtherCAT communication
of the device is in working condition
Green Blink,
Red Blink
Startup Startup blink sequence
Red On
Application Controller
Failure
A critical communication or application controller error
has occurred
Double Red
Flash
Process Data
Watchdog Timeout or
EtherCAT Watchdog
Timeout
An application watchdog timeout has occurred
Single Red
Flash
Local Error
Slave device application has changed the EtherCAT
state autonomously, due to local error
Red Blinking
Invalid Configuration
General configuration error