Configuring Your Server 4-23
Console Redirection
The following screen appears if you select "Console Redirection" on the Server menu and press
Enter.
See the table below for the items.
Option Parameter Description Your Setting
BIOS Redirection
Port
[Disabled]
Serial Port A
Serial Port B
Specify the serial port to which a
remote console is connected.
ACPI Redirection
Port
[Disabled]
Serial Port A
Serial Port B
Specify the serial port to which an
ACPI console is connected.
Baud Rate 9600
[19.2k]
38.4k
57.6k
115.2k
Specify the baud rate used for the
interface with successive remote
consoles.
Terminal Type [PC ANSI]
VT100+
VT-UTF8
Specify the type of remote console.
Flow Control None
XON/XOFF
[CTS/RTS]
CTS/RTS+CD
Specify the flow control method.
Remote Console
Reset*
[Disabled]
Enabled
Specify whether to enable or disable
the reset command issued from
remote console.
[ ]: Factory-set
* Displayed only when Remote Management Card (option) is installed.