Conditions to Conform with EU Directives
The wiring example shown below is one of our recommendations for the conformity with the EU Directives.
Figure 1: Wiring diagram (Example)
Environmental conditions
The Driver Unit must be used in the environmental condition of Pollution Degree1 or 2 as specified by
IEC60664-1. The Driver Unit shall be installed into a control panel with the structure that does not allow
penetration of water, oil or dust (IP54).
Power source
The Driver Unit Model EDD shall be used in the environmental condition of “Over-voltage category III”
as specified by IEC60664-1.
Circuit breaker
Install a circuit breaker that conforms to IEC standard and UL safety standard between the power source
and the Driver Unit.
Noise filter
Install a noise filter between the power source and the Driver Unit.
Ferrite core
Ferrite cores for signal cable shall be set to the power cable, the Motor cable and the resolver cable.
Protective Grounding
Be sure to ground the protective grounding terminal of the Driver Unit Model EDD to the protective
ground (PE) of the control panel for a measure against electrical shock.
Table 2: List of recommended parts